Research and Development Company of the Republic of Belarus in Optolelectronics

PELENG SF-12 Actinometer

PELENG SF-12 Actinometer
CAPABILITIESDirect solar irradiance measurement in 0.3 to 40.0 micron range.
COMPLETE SET
  • sensor unit with cover;
  • electronic unit (optional);
  • diaphragm;
  • special wrench;
  • installation kit;
  • software.
  • CERTIFICATES
  • № 8044 issued by the State Committee for Standardization of the Republic of Belarus;
  • № 51050 isssued by Federal Agency on Technical Regulation and Metrology (Russian Federation)
  • № 8779 issued by the Commitee for Technical Regulation & Metrology of Ministry of Industry and New Technologies
  • of the Republic of Kazakhstan.
  • Spectral range, micron0,3 ÷ 40,0
    Irradiance range, kW/m20,04 ÷ 1,10
    Permissible nonlinearity± 0,01
    Conversion factor, mv m2/kw, min8
    Output resistance, Ω, max30
    Response time, s, max30
    Permissible main relative irradiance error, %± 4
    Ambient temperature induced permissible additional irradiance error, per each 10°C of temperature deviation from 20°С, %± 1
    Power supply voltage (50 Hz ), V:
    - electronic unit
     
    36,0 ± 3,6
    Overall dimensions, mm, max:
    - sensor unit
    - electronic unit
     
    180 × 90 × 70
    185 × 160 × 95
    Weight, kg , max: 
    - sensor unit
    - electronic unit
     
    1,0
    2,4
    Operation environment: 
    - ambient temperature, °C
    - relative air humidity at +25°C, %
     
    -50 ...+50
    100